Uncertainty of evaluation periods masonry buildings INFONAVIT type at Chilpancingo, Guerrero

Authors

DOI:

https://doi.org/10.33064/iycuaa2014633609

Keywords:

masonry, vibrate periods, stiffness, elastic modulus, shear modulus, torsion

Abstract

The representative masonry buildings evaluated are located at the 3rd section of the INFONAVIT neighborhood in Chilpancingo, Guerrero (Mexico). In order to evaluate the periods of vibration of these structures, classical methods and analytical models, as well as in-situ accelerometric records on buildings were applied, and then compared to find out variations among these methods. In addition, experimental and accelerometric instrumentation for a two story masonry dwelling, built and tested at the National Center for Disaster Prevention (CENAPRED), were used to perform additional assessments. In this way, for a five storied building, the ratio between the fundamental period for a classical and an analytical method was 54.38%; and 50.56% for a ratio between a classical and an accelerometric method. In the case of a two storied masonry building, a ratio between a classical and an analytical method was 63.37%.

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

Author Biographies

Hermenegildo Peralta Gálvez, Universidad Autónoma de Guerrero

Maestría en Ingeniería Sísmica, Unidad Académica de Ingeniería

Sulpicio Sánchez Tizapa, Universidad Autónoma de Guerrero

Unidad Académica de Ingeniería

Roberto Arroyo Matus, Universidad Autónoma de Guerrero

Unidad Académica de Ingeniería

References

• BARGHI, M. y AZADBAKHT, M. Evaluating the Effect of Masonry Infills on Natural Period of Buildings with Moment-resisting Frame. Tehran, Iran: Wiley Online Library, pp. 649-650, 2009.

• CARBAJAL, L. E. Variación de las propiedades dinámicas de un edificio de concreto reforzado. Tesis de Licenciatura. Guerrero, México: Universidad Autónoma de Guerrero. Unidad Académica de Ingeniería, pp. 6-8, 2005.

• CARRILLO, W. J. Estimación de los periodos naturales de vibración de viviendas de baja altura con muros de concreto. Ciencia e Ingeniería Neogranadina, 19(1). Universidad Militar Nueva Granada, pp. 41. Colombia, 2009.

• COORDINACIÓN DE INVESTIGACIÓN Y ESTUDIOS DE POSGRADO. Reporte interno de la evaluación estructural de edificios de la Unidad Habitacional de INFONAVIT en Chilpancingo, Gro. Guerrero, México: Universidad Autónoma de Guerrero. Unidad Académica de Ingeniería, 2010.

• GOBIERNO DEL DISTRITO FEDERAL (GDF). Normas técnicas complementarias para diseño por sismo. Gaceta Oficial del Distrito Federal, Decimacuarta época(Tomo II): 55-77, 2004.

• KWON, O. S. y SOO, K. E. Evaluation of building period formulas for seismic design. Rolla, Missouri, USA: Wiley Online Library, pp. 1569-1572, 2009.

• PERALTA, H. Determinación de periodos de vibrar de edificios de la Unidad Habitacional de INFONAVIT en Chilpancingo, Gro. Reporte interno de la Coordinación de Investigación y Estudios de Posgrado. Guerrero, México: Universidad Autónoma de Guerrero. Unidad Académica de Ingeniería, 2013.

• PÉREZ, J. J. Guía de análisis de estructuras de mampostería. México, D. F., México: Sociedad Mexicana de Ingeniería Estructural, A. C., pp. 20-35, 2012.

• RAMÍREZ, M. y GUERRERO, J. J. Cambio en los periodos naturales de vibración de una estructura de mampostería reforzada de 5 niveles. XII Congreso Nacional de Ingeniería Estructural. León, Guanajuato, México, 2000.

• SÁNCHEZ, T. et al. Estudio experimental sobre una estructura de mampostería confinada tridimensional, construida a escala natural y sujeta a cargas laterales. México: Centro Nacional de Prevención de Desastres (CENAPRED), pp. 914-915, 1996.

• SAP2000 NO-LINEAL VERSIÓN 15.0. Para diseño y análisis estructural.

Published

2014-12-31

Issue

Section

Artículos de Investigación

Categories