Fecal coliform removal in anaerobic lagoons using a graphical method
DOI:
https://doi.org/10.33064/iycuaa2024914508Keywords:
Lagoon systems, retention time, fecal coliformAbstract
Anaerobic lagoons remove organic matter in the absence of oxygen and must be designed considering facultative or aerated lagoons, to continue with the treatment and at the same time re-oxygenate the wastewater. The purpose of this document is to determine two graphs to calculate the elimination of fecal coliforms in anaerobic lagoons. An application example is included with the traditional method adopted by the Instituto Mexicano de Tecnología del Agua y la Comisión Nacional del Agua, later the graphs previously prepared are used. The results show the same values calculated with the traditional criteria.
Downloads
Metrics
References
• Adrian, D. D.; & Sanders, T. G. (1998). Oxygen sag equation for second-order BOD decay. Water Research. 32(3):840-848. doi: doi.org/10.1016/S0043-1354(97)00259-5
• Borsuk, M. E.; & Stow, C. A. (2000). Bayesian parameter estimation in a mixed-order model of BOD decay. Water Research. 34(6): 1830-1836. doi: https://doi.org/10.1016/S0043-1354(99)00346-2
• Collí, M.J.; Rico, M. M.; Rivas, H. A.; Escalante, E. V. E. & Luyendijk, R. (1992). Manual simplificado para el diseño, operación y evaluación de lagunas de estabilización de aguas residuales. Comisión Nacional del Agua, Instituto Mexicano de Tecnología del Agua. Jiutepec, México. 32 p.
• Conagua (1997). Manual de diseño de agua potable, alcantarillado y saneamiento. Paquetes tecnológicos para el tratamiento de excretas y aguas residuales en comunidades rurales. Comisión Nacional del Agua, Instituto Mexicano de Tecnología del Agua. Jiutepec, México. 318 p.
• Conagua (2016). Manual de diseño de agua potable, alcantarillado y saneamiento. Manual de diseño de lagunas de estabilización. Comisión Nacional del Agua, Instituto Mexicano de Tecnología del Agua. Jiutepec, México. 186 p.
• Cortés-Martínez, F.; Treviño-Cansino, A.; García, M. A. A.; & Vélez, J. G. L. (2020). Diseño gráfico para la materia orgánica y el tiempo de retención en lagunas facultativas/Graphic design for organic matter and retention time in facultative lagoons. Tecnología y ciencias del agua, 11(2), 158-189. doi: https://doi.org/10.24850/j-tyca-2020-02-04
• Ellis, K.V.; & Rodríguez, P. C. C. (1995). Multiple regression design equations for stabilization ponds. Water Research. 29(11): 2509-2519. doi: 10.1016/0043-1354(95)00081-u
• Kaya, D.; Dilek, F. B. & Gökcay, C. F. (2007). Reuse of lagoon effluents in agricultura by post-treatment in a step feed dual treatment process. Desalination. 215(1-3): 29-36. doi: 10.1016/j.desal.2006.11.013
• Kehl, O.; Wichern, M.; Lübken, M.; Horn, H. (2009). Analysis of design approaches for stabilization ponds under different boundary conditions. A comparison. Ecological Engineering. 35(8): 1117-1128. doi: https://doi.org/10.1016/j.ecoleng.2008.12.022
• Kohn, T.; Mattle, M. J.; Minella, M. & Vione, D. (2016). A modeling approach to estimate the solar disinfection of viral indicator organisms in waste stabilization ponds and surface waters. Water research. 88: 912-922. doi: https://doi.org/10.1016/j.watres.2015.11.022
• Mara, D. D. (2004). Domestic wastewater treatment in developing countries. Routledge
• Metcalf and Eddy Inc. (1991). Wastewater engineering treatment, disposal, and reuse. New York, USA: McGraw-Hill. 752 p.
• Morales, R. S.; Domínguez, E. R. & Mata, M. M. (2016). Procedimiento gráfico para la implementación del diseño estocástico – bajo condiciones de incertidumbre y variabilidad – de unidades naturales de tratamiento de aguas residuales. Afinidad. 73(575): 219-225.
• Naddafi, K.; Hassanvand, A. S.; Dehghanifard, E.; Faezi-Razi, D.; Mostofi, S.; Kasaee, N.; Nabizadeh, R. & Heidari, M. (2009). Performance evaluation of wastewater stabilization ponds in Arak-Iran. Journal of Environmental Health Science & Engineering. 6(1): 41-46.
• Reynolds, D. M. & Ahmad, S. R. (1997). Rapid and direct determination of wastewater BOD values using a fluorescence technique. Water Research. 31(8): 2012-2018. doi: https://doi.org/10.1016/S0043-1354(97)00015-8
• Rolim, M. S. (2000). Sistemas de lagunas de estabilización, cómo utilizar aguas residuales tratadas en sistemas de regadío. Santa Fe de Bogotá, Colombia: Nomos. 370 p.
• Treviño-Cansino, A. & Cortés-Martínez, F. (2016). Método de diseño reducido para lagunas de estabilización. Revista mexicana de Ciencias Agrícolas. 7 (4): 729-742.
• Uhlmann, D.; Recknagel, F.; Sandring, G.; Schwarz, S. & Eckelmann, G. (1983). A new design procedure for waste stabilization ponds. Water Pollution Control Federation. 1252-1255pp.
• Xinglong, J. & Boyd, C. E. (2005). Measurement of 5-day biochemical oxygen demand without sample dilution or bacterial and nutrient enhancement. Aquacultural engineering. 33(4): 250-257. doi: https://doi.org/10.1016/j.aquaeng.2005.02.005
• Yánez, F. (1993). Lagunas de estabilización: Teoría, diseño, evaluación y mantenimiento. Cuenca, Ecuador. 493 p.
Published
How to Cite
License
Copyright (c) 2024 Facundo Cortes-Martínez, Arturo Tadeo Espinoza-Fraire, Francisco Luis Camporredondo-Reyes, Rosa Angélica Zamora-Ríos
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
Las obras publicadas en versión electrónica de la revista están bajo la licencia Creative Commons Atribución-NoComercial-CompartirIgual 4.0 Internacional (CC BY-NC-SA 4.0)